• <abbr id="ck0wi"><source id="ck0wi"></source></abbr>
    <li id="ck0wi"></li>
  • <li id="ck0wi"><dl id="ck0wi"></dl></li><button id="ck0wi"><input id="ck0wi"></input></button>
  • <abbr id="ck0wi"></abbr>
  • <li id="ck0wi"><dl id="ck0wi"></dl></li>
  • Home >

    Shop Selection Skills Specification

    2014/6/6 22:33:00 34

    PropertySelection CriteriaShop Skills

    < p > 1., the rectangular shape is the best and the ratio of length to width should not exceed 2:1. 4:3 and 5:4 are better.

    < /p >


    < p > 2., the shape of the house should be divided without partitions, with complete space and good permeability. There is no separation between the hollow and middle elevators for public use, although they are partitions, but they are all removable lightweight partitions.

    < /p >


    < p > 3. the main opening is a href= "http://www.91se91.com/news/index_c.asp" > Street < /a >, and the opening is not less than 30 meters.

    < /p >


    Apart from considering the business area, the area of < p > 4. has the area of auxiliary rooms and other auxiliary rooms. The area of auxiliary rooms and business premises should be divided according to the proportion of 2:8.

    < /p >


    < p > 5., the depth requirement should be not less than 30 meters, or at least 30 meters above, between 30 and 60.

    < /p >


    < p > 6. column spacing should be more than 6 meters, or at least can be used as the main part of shops should be more than 6 meters.

    < /p >


    < p > 7. storey height should be counted at the bottom of the beam. It should be not less than 4 meters, and it should be 4.5 to 5.5 meters. The highest should not be 8 meters.

    < /p >


    < p > 8. the distribution of the rented area on the floor is the best in all the first floor. The store can be located on the one or two floor, not more than three storeys. If the shop is layered, the shop area should not be less than 2000 or 4000 square meters.

    < /p >


    < p > 9. each layer is connected by an automatic sidewalk, and the automatic sidewalk is set up in the store with the left side attached to the wall or the wall. The property shall provide 3*30 square meters of installation position in the above location.

    < /p >


    < p > 10. the ground load of the first floor is not less than 500KG, and the dynamic load of each floor is not less than 350KG.

    < /p >


    Buildings with < p > 11. used as < a href= "http://www.91se91.com/news/index_c.asp" > shopping mall < /a > should have strong visibility and should be tall in volume. At least two directions, at least 50 meters away, can see shops.

    < /p >


    < p > 12. electricity consumption can be determined according to the size of the store and equipment configuration, but at least not less than 500KW. The power supply mode is better than the double circuit of the power supply.

    < /p >


    < p > 13. high and low voltage distribution equipment should be complete, or there can be installed high and low voltage distribution equipment location.

    < /p >


    < p > 14. the water supply pipe should be connected to the indoor room with fire pools and hydrants.

    < /p >


    < p > 15., there are sewage pipes and rainwater pipes connected to the municipal pipe network. Sewage should be equipped with special oil separation and drainage pools, and rainwater and sewage will be discharged separately.

    < /p >


    < p > 16., pipe gas should be connected to the room.

    < /p >


    < p > 17. air conditioning equipment, the central air-conditioning is best provided by the owner, and the air conditioning refrigeration volume should be between 120W~180W or free to install the central air-conditioning main engine room and cooling tower installation position.

    < /p >


    < p > 18. the selected property shall be provided by the owner (or provided with the installation position) with a cargo capacity of not less than 2 tons. The width of the opening of the cargo ladder shall not be less than 1.4 meters, and the cargo ladder is in a proper position, which can be conveniently accessible to all storehouses or back-up warehouses without affecting the customer's moving line.

    < /p >


    < p > 19. < a href= "http://www.91se91.com/news/index_c.asp" > passenger ladder < /a >: the property between the selected properties is preferably provided by the owners with automatic sidewalks, or the installation location of 4*30 square meters, the width of the automatic sidewalk is not less than 1 meters, and the slope is not more than 12 degrees.

    < /p >


    < p > 20. cold chain computer room: the selected property should have a cold chain machine room of not less than 12 square meters.

    < /p >


    < p > 21. the selected property should have a smoke exhaust well location.

    < /p >


    < p > 22. fire fighting system: the fire fighting system should be designed according to class B or above, or the owner should install the fire protection system at least.

    < /p >


    < p > 23. the selected property should be displayed in the top strokes, the location of the side strokes and the advertising location for free use.

    < /p >

    • Related reading

    Improve Clothing Store Savor Shop Decoration Skills

    Management treasure
    |
    2014/6/6 18:44:00
    28

    Winters Laundry Tips: Dry Cleaners Should Focus On Innovative Services.

    Management treasure
    |
    2014/6/6 16:15:00
    52

    Five Notices For Discount Sale In Clothing Stores

    Management treasure
    |
    2014/6/4 11:05:00
    16

    Shop Location, Do Not Blindly Win At The Starting Line.

    Management treasure
    |
    2014/6/4 9:33:00
    15

    A Practical Strategy To Check Underwear Stores

    Management treasure
    |
    2014/6/3 17:10:00
    66
    Read the next article

    Guangzhou Footwear Exhibition Official Intelligent Shoe Machine To Play The Leading Role

    It is worth mentioning that, in order to rush to this exhibition, ORISOL will display 4 new computer automatic sewing machines, automatic sewing machine shoe eyelet riveting machines that have just been successfully developed at the end of April. "Products follow the basic idea of" one variable and three in one ". In fact, this is the direction that the industry has been trying to make in the past two years, and finally we are the first to develop it. Dai Jiaxin, director of ORISOL m

    主站蜘蛛池模板: 伊人222综合| 欧美成人免费香蕉| 69久久夜色精品国产69| 羞羞网站免费观看| 男人团vip每日更新番号库| 日本中文字幕在线电影| 国产福利专区精品视频| 亚洲综合校园春色| 一级特色大黄美女播放网站| 香港经典a毛片免费观看看| 欧美日韩在线观看视频| 天天狠天天透天干天天怕∴ | 又大又粗又爽a级毛片免费看| 乱人伦人妻中文字幕无码久久网| 96xxxxx日本人| 狠狠色婷婷久久一区二区三区| 成人免费视频国产| 国产v精品欧美精品v日韩| 久久影院秋霞理论| 欧美videos极品| 欧美一级久久久久久久大片| 国产精品日韩欧美一区二区三区| 亚洲精品色午夜无码专区日韩| 97视频在线观看播放| 波多野结衣cesd—819高清| 天天做天天爱夜夜爽| 免费二级毛片免费完整视频| 一本之道在线视频| 精品国产污污免费网站入口| 成人无码嫩草影院| 国产69精品久久久久9999| 久久久久99精品成人片直播| 被夫上司连续侵犯七天终于| 日本精品视频在线观看| 国产亚洲精品精品国产亚洲综合| 久久国产精品久久| 草草影院国产第一页| 把腿扒开做爽爽视频在线看| 和武警第一次做男男gay| 两个人看的日本高清电影| 精品无码国产自产拍在线观看蜜 |